Beam Span Reference
Continuous Span: Single Span × 1.2
Double Members (×90): Single Span × 1.4
Disclaimer: Indicative only. Always verify with AS 1684 span tables and consult an engineer.
Note: Spans shown assume normal domestic loading with load width up to 1.8m. Greater load widths may reduce allowable spans.
Beam Span Calculator: Timber Span Tables Australia
Australian residential construction uses over 4.2 million cubic metres of structural timber annually (ABARES, 2024). Getting your beam and joist spans right is critical: undersized members risk structural failure, while oversized members waste money. This calculator uses AS 1684.2 span table data to find maximum spans for floor joists, ceiling joists, rafters, bearers, verandah beams, and deck joists.
Maximum Span Table: Floor Joists (MGP10, Domestic Load)
| Timber Size | 450mm Spacing | 600mm Spacing |
|---|---|---|
| 90×45 | 1,600mm | 1,450mm |
| 120×45 | 2,150mm | 1,950mm |
| 140×45 | 2,500mm | 2,250mm |
| 190×45 | 3,350mm | 3,000mm |
| 240×45 | 4,250mm | 3,800mm |
| 290×45 | 5,100mm | 4,600mm |
Timber Stress Grade Factors
| Grade | Span Factor | Common Use |
|---|---|---|
| MGP10 | 1.0× | General framing, studs |
| MGP12 | 1.1× | Joists, rafters |
| MGP15 | 1.2× | Beams, lintels |
| F7 Hardwood | 1.05× | Basic hardwood framing |
| F14 Hardwood | 1.25× | Structural hardwood |
| F17 Hardwood | 1.35× | High-grade hardwood |
| LVL Engineered | 1.6× | Long spans, beams |
How the Calculation Works
The maximum span is determined by: Max Span = Base Span (from AS 1684.2 table) × Timber Grade Factor. For example, a 190×45 MGP12 floor joist at 450mm centres: 3,350mm × 1.1 = 3,685mm maximum span.
How to Read an AS 1684 Span Table
The calculator gives you a quick estimate. The span a certifier checks comes from the AS 1684 span tables, which are read differently from the factor method above. Six things decide which table, and which row, applies to your member.
1. Wind classification comes first
AS 1684 is not one set of tables. Before you open any of them you need the site’s wind classification under AS 4055, worked out from the wind region, terrain category, topography and shielding. AS 1684.2 covers non-cyclonic N1 to N4, AS 1684.3 covers cyclonic C1 to C3, and AS 1684.4 is a simplified version for N1 and N2 houses only. A C4 site is outside AS 1684 and needs an engineer.
2. Each stress grade has its own supplement
The span tables sit in supplements to the Standard, one for each stress grade in each wind class group: MGP10, MGP12 and MGP15, and the F-grades, seasoned and unseasoned, softwood and hardwood. Use the supplement for the grade you are actually buying. A higher grade does not lift every span by the same percentage. The gain changes with the size and spacing of the member, so a span read from one grade and scaled up is an estimate, not a table value.
3. Find the member, then its load width
Each member type has its own table: floor joists, bearers, rafters, ceiling joists, lintels and verandah beams. Joists are read by size and spacing. Bearers and lintels also need a load width:
- Floor load width (FLW): half the joist span on each side of the bearer, added together, plus the full length of any cantilever.
- Roof load width (RLW): the width of roof that bears on the member, measured on the rake. It is different for coupled, cathedral and trussed roofs, so work it out from the framing rather than a rule of thumb.
A bearer that also carries a loadbearing wall needs both, plus whether the roof is sheet or tile. A tiled roof is far heavier, and the tables are split on it.
4. Single or continuous span
A single span is supported at two points. A continuous span runs over one or more intermediate supports and generally allows a longer span from the same member. It only counts as continuous if no span is more than twice the length of another, and the member is not notched or joined over the internal supports. Some manufacturer tables set a stricter ratio, so read their notes.
5. Measure span and spacing the way the tables do
Span is the clear distance between the faces of the supports, not centre to centre. Spacing is measured centre to centre between members. Rafter spans are measured on the rake, not on plan. A cantilever past the last support has its own column and its own limit.
6. LVL, glulam and I-joists are not in AS 1684
The AS 1684 span tables only cover sawn timber. For LVL, glulam and I-joists, use the manufacturer’s span tables for that exact product.
If the job falls outside what the tables cover, such as more than two storeys, walls over 3 metres, a roof pitch over 35 degrees, a site above C3 or an unusual point load, it needs an engineer. Check the current edition before you rely on a figure: AS 1684.2 and AS 1684.3 were both reissued in 2021 and amended in 2024.
Frequently Asked Questions
What is the maximum span for a 190×45 floor joist?
Using MGP10 timber at 450mm centres, a 190×45 floor joist can span up to 3,350mm. At 600mm centres, the maximum reduces to 3,000mm. Higher grades like MGP12 or F14 increase the span.
What timber grade should I use for floor joists?
MGP10 is the most common for residential floor joists. MGP12 is used when longer spans are needed. For exposed applications, F17 hardwood or LVL provides greater spanning capacity.
Does stud spacing affect beam span?
Yes. Closer spacing (450mm) distributes load across more members, allowing longer spans. At 600mm centres, each member carries more load, reducing maximum span by 10–15%.
Do I need a structural engineer for beam sizing?
For standard residential construction, AS 1684.2 span tables are acceptable. For unusual loads, multi-storey buildings, or commercial applications, a structural engineer’s certification is required.
Stop Guessing. Start Building Smarter.